|
|
||||||||||||||
|
|
|||||||||||||||
RESEARCH PAPER |
1 University of Rome "La Sapienza", 5 Ple Aldo Moro, 00185 Rome, Italy
2 Department of Epidemiology ASL Roma E, Rome, Italy
3 Istituto Superiore di Sanità, Viale Regina Elena, 299, 00161 Rome, Italy
Correspondence to:
Pasquale Valente
Istituto Superiore di Sanità, Dipartimento Tecnologie e Salute, Viale Regina Elena 299, 00168 Roma; pasquale.valente{at}iss.it
Received 14 December 2006
Accepted 4 May 2007
| ABSTRACT |
|---|
|
|
|---|
Methods: We compared indoor air quality before and after the smoking ban by monitoring the indoor concentrations of fine (<2.5 µm diameter, PM2.5) and ultrafine particulate matter (<0.1 µm diameter, UFP). PM2.5 and ultrafine particles were measured in 40 public places (14 bars, six fast food restaurants, eight restaurants, six game rooms, six pubs) in Rome, before and after the introduction of the law banning smoking (after 3 and 12 months). Measurements were taken using real time particle monitors (DustTRAK Mod. 8520 TSI; Ultra-fine Particles Counter-TRAK Model 8525 TSI). The PM2.5 data were scaled using a correction equation derived from a comparison with the reference method (gravimetric measurement). The study was completed by measuring urinary cotinine, and pre-law and post-law enforcement among non-smoking employees at these establishments
Results: In the post-law period, PM2.5 decreased significantly from a mean concentration of 119.3 µg/m3 to 38.2 µg/m3 after 3 months (p<0.005), and then to 43.3 µg/m3 a year later (p<0.01). The UFP concentrations also decreased significantly from 76 956 particles/cm3 to 38 079 particles/cm3 (p<0.0001) and then to 51 692 particles/cm3 (p<0.01). Similarly, the concentration of urinary cotinine among non-smoking workers decreased from 17.8 ng/ml to 5.5 ng/ml (p<0.0001) and then to 3.7 ng/ml (p<0.0001).
Conclusion: The application of the smoking ban led to a considerable reduction in the exposure to indoor fine and ultrafine particles in hospitality venues, confirmed by a contemporaneous reduction of urinary cotinine.
Abbreviations: CIAA, Clean Indoor Air Act; ETS, environmental tobacco smoke; PM, particulate matter; RIA, radioimmunoassay; RSP, respirable suspended particle; UFP, ultrafine particle
Keywords: secondhand smoke; cotinine; particulate; ultrafine; smoking ban
The application of the law banning smoking in indoor public places in Italy on 10 January 20051 follows other smoking bans in the world. The Smoking Ordinance (Labor code 6404.5) of January 1998, extended the smoking ban to bars, game rooms, bingo parlours, casinos, and other public locations in California, and made it the first state to outlaw smoking in all indoor public places. Similar legislation has been subsequently adopted in India, Ireland, Malta, New Zealand (2004), Norway, and South Africa (2000). It is expected that smoking bans will be adopted in several other European countries in the near future, although the introduction of laws that prohibit smoking have often been highly contested.2
Environmental tobacco smoke (ETS) is an air pollutant made up of a complex mixture of around 4000 chemicals, some 50 of which are carcinogens.3 Exposure to ETS is causally associated with several adverse health effects, including lung cancer and heart disease in adults, exacerbation of asthma, lower respiratory illnesses, ear infections, and other diseases in children and infants.4–6 A recent report of the European Respiratory Society estimates that a total of 80 000 adults in Europe in 2002 died from exposure to ETS, including 7000 subjects between 20–64 years of age who were exposed at work (2800 non-smokers).7
Hospitality venues where smoking is permitted are characterised by elevated ETS exposure. Siegel8 showed that ETS exposure in bar and restaurant employees is 1.5–4.4 times higher than in subjects who live with a smoker. Although the general public spends a limited amount of time in indoor public places, the resulting ETS exposure is relevant and health effects are also likely, and smoking bans seem to be associated with a rapid positive effect on ischaemic heart disease morbidity.9,10
Vapour phase nicotine and particulate matter (PM2.5) are the most commonly used indicators to evaluate environmental exposure to ETS.11 Numerous studies have shown that tobacco smoke plays a major part in determining the concentration of particulate matter indoors. In addition, ETS is, like all other byproducts of combustion, made up of a considerable number of ultrafine particles (UFP), with a diameter <0.1 µm, since the average aerodynamic diameter of ETS particles is approximately 0.2 µm.12 Ultrafine particles are an important cause of adverse effects as a consequence of their large total surface, their large alveolar deposition, inflammatory capability, and their possibility to translocate in the general circulation.13 Main indoor sources of UFP are smoking, cooking, candles, and chemical reactions (for example, terpens and ozone).14 Nicotine is principally metabolised into cotinine by the liver; it has a half life of around 18 hours and is generally considered the best indicator of nicotine intake.15 Urinary cotinine levels correlate with levels of environmental nicotine and with self reported ETS exposure.16
The evidence of the health effects of airborne particles comes from several lines of scientific investigation, from cellular and animal studies to large epidemiological investigations. Health effects include premature mortality, cardiorespiratory morbidity, and lung cancer. The World Health Organization has recently issued a global update of the Air Quality Guidelines.17 The annual average guideline value of 10 µg/m3 for PM2.5 was chosen to represent the lower end of the range over which significant effects on survival have been observed. The 24 hour PM2.5 guideline is 25 µg/m3. While there is considerable toxicological evidence of potential detrimental effects of ultrafine particles on human health, the existing body of epidemiological evidence was insufficient to reach a conclusion on the exposure–response relation to ultrafine particles and no recommendation was provided in the guideline for concentrations of ultrafine particles.
In order to evaluate the efficacy of the new legislation in public indoor environments in Italy, we studied changes in environmental concentrations of fine and ultrafine particles, as well as urinary cotinine in employees of public establishments, before and after (in the third and 12th month) the implementation of the law banning smoking.
| MATERIALS AND METHODS |
|---|
|
|
|---|
PM2.5 was measured with a real time aerosol monitor (DustTrak, Model 8520 TSI), equipped with a sampling nozzle to collect fine particles (PM2.5). In the same establishments, ambient ultrafine particles were counted using a condensation particle counter: P-Trak Monitor (Mod. 8525 UPC TSI). At the same time, continuous measurements were taken of temperature, relative humidity, CO2, and air velocity (with Q-Trak Plus TSI). A survey of all these parameters was taken in the outside environment for purposes of comparison. The instruments took measurements every 10 seconds, and recorded the average reading every minute, in both smoking and non-smoking areas. Every day the instruments were recalibrated (to zero). Instruments were positioned inside, an average height of 0.8 metre above the tables and at least 3 metres from the entrance, in the centre when possible, and at least 2 metres from any potential pollutant source (gas stove, espresso machine, grill). The total measurement time was 20 minutes. Other variables recorded included size of location (square metres), air ventilation (natural or mechanical), smoking regulations, the presence of ashtrays and smokers, and the number of employees and customers present. Outdoor measurements of PM2.5 and UFP counts were taken nearby, 0.8 metre off the ground, and weather and traffic conditions were recorded.
PM2.5 measurements with DustTrak were later gravimetrically calibrated based on empirically derived correction equations. For one month in winter and one month in summer, in two environments, one reserved for smokers and the other for non-smokers, PM2.5 measurements were taken both with DustTrak and an active air pump (Skypost PM TCR-Tecora) with an air flow of 2.3 m3/h conforming to specified European protocols for measuring PM2.5.18 The particles were collected on a 47 mm filter membrane. Each measurement was conducted over 8 hours. The measurements were carried out daily, in two phases (first phase from 8.00–16.00, the second phase from 20.00–04.00). The mass concentration of particulate collected was determined by manual gravimetric method, using a Sartorius scale with a resolution of 1 µg, after the filters were pretreated for at least 48 hours at 50 (SD 5) RH%, 293 (SD 1) K (in a room with controlled temperature and relative humidity).19 Based on the linear regression of PM2.5 concentrations measured with Dust Trak/manual gravimetric method (RFM), two correction equations were applied to the PM 2.5 data: x = (y+21.01)/4.01 for smoking environments (y = 4.0132 (1.0544)x–21.048 (72.5159)) R2 = 0.7567, and x = (y+9.1)/2.66 for smoke free environments (y = 2.6587 (0.1932)x–9.108 (3.8360)) R2 = 0.917.
All non-smoking employees of the 40 facilities were asked to provide a urine sample, contemporaneously with PM2.5 measurements. An interview was completed for each subject, on personal data and information to evaluate subjective exposure to passive smoke in the workplace and at home (presence of smoke, hours of exposure per week). Urine samples were stored at –80°C. Urinary cotinine was measured using radioimmunoassay (RIA), according to the method described by Van Vunakis et al.20 A cut-off of 100 ng/ml was employed to distinguish active smokers from non-smokers. Two subjects of the first phase were excluded from the analyses with cotinine levels of >100 ng/ml.
Arithmetic and geometric means were calculated. Levels of environmental and biological data from the three periods were compared with the Mann-Whitney test. The results were confirmed using separate linear regression analysis with the log transformation of PM2.5, UFP, and urinary cotinine as the dependent variable and an indicator variable for the three periods of the assessment as the independent variable. The data were analysed using Stata 8 software.
| RESULTS |
|---|
|
|
|---|
|
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Few studies have reported objective ETS exposure data from public locations, even fewer have used environmental PM2.5 and cotinine concentrations as the exposure indicator. Measurements taken in residences and offices22 indicate good correlation between ambient nicotine and ambient particulate concentrations. This has been particularly true in locations studied where (a) there is regular smoking, (b) microenvironments are in a steady state, and (c) the measurement periods are significantly longer than necessary for smoke diffusion.12 PM2.5 is a widely accepted indicator to evaluate indoor air quality and is a valid exposure marker of ETS.
The real time measurements method (DustTrak) was well correlated with the gravimetric reference method, but it constantly overestimated PM2.5 levels (2.66 times higher), and the overestimation was even higher in the presence of ETS (4.01). The values measured with DustTrak, once corrected, resulted in line with measurements from other studies that used the gravimetric method. The mean (corrected) PM2.5 from the entire pre-law sample was 119.3 µg/m3. Recently, measurements with the gravimetric method showed average concentrations of PM2.5 to be 114.5 µg/m3 in the smoking sections of 59 pubs and bars.23 Siegel reported a weighted respirable suspended particle (RSP) average of 117 µg/m3, based on 12 studies in restaurants.8 These values are analogous to those reported by Ellingsen24 for total particulate in restaurants in Norway (115 µg/m3). Outdoor concentration levels after correction also appear to be analogous to those calculated with the reference method for Rome.
Our data confirm the presence of elevated levels of ETS exposure in indoor hospitality venues, similar to those observed in England,23 in Ireland,28 in Norway,24 and in the US,25–27 before the smoking bans in restaurants and bars. Those who work in environments where there are no smoking restrictions for customers have three times higher exposure levels to ETS than employees of businesses where smoking is restricted to a special area. They also present cotinine levels that are much higher than employees of completely non-smoking businesses.29
As in Ireland, Norway, and the US, smoking bans in Italy also have drastically reduced ETS pollution. Our study showed that PM2.5 was reduced by two-thirds and urinary cotinine by 73%. A statistically significant reduction in ETS pollution was also seen in establishments that already prohibited smoking. The significant reduction in air pollution is probably the result of both the rigorous manner in which the law was enforced, and of the great reduction in the number of businesses with smoking sections. In smoking sections, the reduction in the particulate concentrations was markedly smaller. One study that measured the changes in RSP levels in 20 restaurants and bars in New York reported an 84% decrease after the Clean Indoor Air Act (CIAA) was put into effect in July 2003.25 Similar results were obtained by Repace in Delaware. Examining the changes produced by the CIAA on the air quality, he found that RSP decreased by 91%, contemporaneously to a 95% reduction of polycyclic aromatic hydrocarbons.26 In a cross sectional study of the hospitality industry, after the CIAA took effect in New York, a significant reduction was shown in urinary cotinine and ETS exposure levels, compared to pre-law levels.27 In particular, the proportion of subjects with undetectable levels of urinary cotinine increased from 3% to 62% after the law, while average values of urinary cotinine decreased from 4.93 ng/ml to 0.30 ng/ml. These studies indicate that most (70–90%) fine particulate concentrations indoors are related to cigarette smoke and that eliminating smoke significantly improves the quality of indoor air, with substantial reduction of health risks. Reductions similar to ours have been verified by using other markers, like salivary cotinine (reduced by 70%) by Mulcahy et al28 in Ireland. In that study, self reported exposure to passive smoke showed a significant reduction from an average of 30 hours to zero hours and was associated with a great reduction (83%) in concentrations of nicotine in the air, from an average of 35.5 mg/m3 to 5.95 mg/m3.26 Ellingsen described exposure to nicotine and indoor particles, before and after the smoking ban was extended to include bars and restaurants in Norway. The mean concentrations of nicotine and total particulate (with gravimetric method) decreased from 28.3 µg/m3 (range 0.4–88.0) and 262 µg/m3 (range 52–662), respectively, to 0.6 µg/m3 (range 0–3.7) and 77 µg/m3 (range 0–261) after the ban. Pearsons correlation between nicotine in the air and total particulate was very good (0.86, p<0.001; n = 48). The geometric average of urinary cotinine concentrations was reduced from 9.5 µg/g creatinine (95% CI 6.5 to 13.7) to1.4 µg/g creatinine (95% CI 0.8 to 2.5) (p<0.001) in 25 non-smokers.20 Similarly to Bates,29 our study also shows that employees of hospitality venues with smoking sections reserved for their customers are still considerably more exposed than those who work in non-smoking businesses.
| What is already known on this subject Some studies have suggested a positive impact of smoking bans on the reduction of ETS exposure. The studies have used airborne nicotine or particulate matter and urinary cotinine
|
| What this study adds In Italy, the smoking ban introduced in 2005 has produced a strong reduction of fine and ultrafine particles exposure in hospitality venues and a 73% reduction of urinary cotinine in employees. The study indicates a strong association between fine particulate matter from environmental smoking and urinary cotinine.
|
Our data also suggest a relation between ETS pollution and ultrafine particles. Smoking is an important source of indoor UFP, but their number is also dependent on other sources like cooking appliances and burning candles30; this could explain the lower relative decrease of UFP when compared to PM 2.5 and urinary cotinine.
| CONCLUSION |
|---|
|
|
|---|
Exposure reduction is predominantly associated with the elimination of smoking areas, while in smoking sections, in spite of air exchange and recycling systems, significant differences in air quality exist. The results of environmental and biological monitoring indicate that in facilities with smoking areas, a residual risk exists for the health of the employees.
| ACKNOWLEDGEMENTS |
|---|
| FOOTNOTES |
|---|
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
G. Cesaroni, F. Forastiere, N. Agabiti, P. Valente, P. Zuccaro, and C. A. Perucci Effect of the Italian Smoking Ban on Population Rates of Acute Coronary Events Circulation, March 4, 2008; 117(9): 1183 - 1188. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS | REGISTER |