Article Text

Download PDFPDF

Assessment of secondhand smoke in international airports in Thailand, 2013
Free
  1. Nipapun Kungskulniti1,2,
  2. Naowarut Charoenca1,2,
  3. Jintana Peesing3,
  4. Songwut Trangwatana3,
  5. Stephen Hamann3,
  6. Siriwan Pitayarangsarit3,
  7. Hatai Chitanondh4
  1. 1Faculty of Public Health, Mahidol University, Bangkok, Thailand
  2. 2Center of Excellence on Environmental Health and Toxicology, Bangkok, Thailand
  3. 3Tobacco Control Research and Knowledge Management Center, Bangkok, Thailand
  4. 4Thailand Health Promotion Institute, Bangkok, Thailand
  1. Correspondence to Naowarut Charoenca, Faculty of Public Health, Mahidol University, 420/1 Rajvithi Rd, Bangkok, Thailand; nao.naowarut{at}yahoo.com

Abstract

Objective To assess secondhand smoke (SHS) exposure in Thai international airports using a fine particulate indicator, particulate matter ≤2.5 μm (PM2.5), and to compare with 2012 exposure findings in international airports in the USA.

Methods Smoking rooms in the four largest international airports that serve the most travellers and with the most operating designated smoking rooms (DSRs) were monitored using PM2.5 monitoring equipment following an approved research protocol for assessing fine particle pollution from tobacco smoke. Monitoring was conducted inside and just outside DSRs and throughout the airport terminals in all four airports. Altogether 104 samples were taken to assess SHS exposure in four airports. Simultaneous samples were taken multiple times in a total of 11 DSRs available for sampling in the research period.

Results Levels of PM2.5 in DSRs were extremely high in all four airports and were more dangerous inside DSRs than in the US airports (overall mean=532.5 vs 188.7 µg/m3), higher outside DSRs than in the US airports (overall mean=50.1 vs 43.7 µg/m3), and at comparable levels with the US airports in the terminals away from DSRs (overall mean=13.8 vs 11.5 µg/m3. Findings show that travellers and employees in or near DSRs in the airports assessed in Thailand are being exposed to even higher levels of SHS than in US airports that still have DSRs.

Conclusions Extremely high levels of SHS in and adjacent to DSR show that these rooms are not providing safe air quality for employees and travellers. These high levels of exposure are above those levels reported in US airports and show the need for remedial action to ensure safe air quality in international airports in Thailand.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Introduction

In 1992, national legislation, the Thai Non-Smokers Health Protection Act, specified a number of measures to protect non-smokers from secondhand smoke (SHS).1 Some measures like allowing designated smoking rooms (DSRs) were inadequate. Incremental changes strengthening the law followed through research evidence of SHS dangers, though slowed by actions taken by the tobacco industry to divert the overall smoke-free movement.2 ,3 The tobacco industry was particularly clever in using the hospitality industry as a front group to make economic and ‘ventilation’ arguments, though these arguments were not credible based on economic and air quality studies.4 Despite industry efforts, air quality studies in Thailand resulted in evidence making Thailand nearly 100% smoke free.5–7

Smoking in airports

Past studies have focused on showing that DSRs do not provide safe air quality for airport employees or customers.8–10 High-income countries like Australia have banned smoking in airports simultaneously with bans on smoking during air travel.11 In contrast, smoking in Thai international airports is still allowed. A recent US study of large hub airports showed that several major airports in the USA still had unacceptable SHS exposure from smoking restaurants, rooms or lounges, even though over 600 US airports of all sizes are smoke free.12 ,13 This rather surprising SHS exposure in US large-hub airports precipitated this study of smoking in Thailand's airports. Thailand's latest regulation to protect the health of non-smokers prohibits smoking in domestic airports, but allows DSRs in international airports.14 Recent evidence showing that most international tourists visiting Thailand prefer smoke-free areas also makes it timely to investigate the actual level of SHS exposure in DSRs in Thailand.15

Methods

In March–April 2013, the four largest international airports in Thailand were selected for study because they had the most operating DSRs. They served an estimated 64 million travellers in 2011. Locations were monitored during at least two periods of morning, afternoon or evening in each airport, including inside DSRs (one in airports A and B; three in airport C; and six in airport D), areas adjacent to the smoking rooms and non-smoking areas. Areas adjacent to smoking rooms were areas 1 m (3.3 ft) from the door of the smoking room at breathing zone height as used in research in the US study.12 These locations were monitored to assess the leakage of SHS to the surrounding areas. Results from non-smoking areas of each airport were compared with results from DSRs and areas adjacent to DSRs. Statistical analysis for the log-transformed data of the three airport locations monitored used analysis of variance.

Particulate matter ≤2.5 μm (PM2.5) was used as an indicator of SHS exposure according to best practice and an expert-developed protocol for such monitoring.16 ,17 The real-time TSI Sidepak AM510 Personal Aerosol Monitor was used, 30 min for each measurement, to determine levels of PM2.5 in µg/m3. Sampling of PM2.5 was done simultaneously inside and adjacent to DSRs by two researchers. The results of each sample taken at 1 min intervals were downloaded onto a computer, and analysed and compared by location. A calibration factor of 0.32 and a flow rate of 1.7 L/min. was used for the data from the three instruments used in measuring PM2.5 levels.

Results

Data from 104 samples overall were analysed for mean levels of PM2.5 from study sites in the four international airports as shown in table 1. The overall mean PM2.5 levels in the smoking rooms were 532.5 µg/m3, 50.1 µg/m3 in areas adjacent to the smoking rooms, and 13.8 µg/m3 in non-smoking areas. The levels of PM2.5 were significantly different for all three areas studied (p<0.05). The high levels of detected PM2.5 for the areas adjacent to the smoking rooms indicate leakage of SHS from inside the smoking rooms. The Spearman rank correlation coefficient (rsp=0.791, 95% CI 0.550 to 0.916, p<0.01) indicates a considerable correlation between the two areas. Figure 1 illustrates how DSR levels had corresponding levels outside DSRs. Non-smoking areas had much lower PM2.5 exposure levels than the areas adjacent to the smoking rooms (13.8 vs 50.1 µg/m3). Levels just outside smoking rooms were about four times the levels in smoke-free areas.

Table 1

Levels of PM2.5 in smoking rooms, adjacent to smoking rooms and non-smoking areas of the four airports

Figure 1

Real time plots of 1 min average values of particulate matter ≤2.5 μm (PM2.5, μg/m3) concentrations during a measurement session in designated smoking room (DSRs) and adjacent to DSRs in a Thai international airport.

The same pattern of PM2.5 levels was observed in all four international airports with the highest levels measured in the DSRs. The levels detected in each of the three locations in every airport were significantly different. Further, the mean level of PM2.5 in the DSR of airport B was alarmingly high, 1793.9 µg/m3, with the area adjacent to the DSR at 155.9 µg/m3. It was noticed that this particular DSR opened onto a small convenience store, already in violation of Thai smoke-free regulations as a licensed public shop. Therefore, smokers inside the DSR and hundreds of travellers and airport employees who used this shop were affected every day.

The overall mean PM2.5 levels in DSRs and areas adjacent to DSRs were higher in Thai international airports than levels found in the USA (532.5 vs 188.7 µg/m3 and 50.1 vs 43.7 µg/m3).

Discussion

SHS exposure in DSRs and adjacent to DSRs in Thailand were much higher than levels found in the USA. For example, in the US Environmental Protection Agency air quality index used to warn the public of air pollution dangers, levels over 250 µg/m3 are hazardous and levels over 40 µg/m3 are considered unhealthy for sensitive groups. SHS has been recognised as the most common source of indoor air pollution, yet it is surprising that exposure levels found in small DSRs in Thailand have reached more than 20 times the 24 h, short time indoor air pollutant level of 25 µg/m3 in WHO guidelines.18

Recent research confirms the extreme dangers of SHS exposure, especially regarding vulnerable populations like babies and children, and the adverse short-term effects of SHS on cardiovascular health.19 It is now clear that smoke-free places can go a long way to eliminate the smoke-related threats to every biological system of the body.20

Though smoke-free policy is desirable in international airports based on the serious health effects known to result from SHS exposure, no action to ban smoking in Thai international airports has yet been taken.

Past document research of tobacco industry consultants and commercial allies shows they have spent considerable time and money to promote ‘accommodation’ or ‘ventilation’ solutions to address SHS exposure indoors.21 Past research shows that these measures do not work.8 Though Thailand has aimed for a comprehensive ban, it is sometimes problematic when one takes only incremental steps towards the adoption of smoke-free areas. Complacency can develop in taking steps to remove SHS in all locations. Once partial measures are adopted, authorities may see these as adequate, compromise positions, and be unwilling to finish the job of protecting the public from SHS when no exposure is the only safe exposure.22

This study is the first undertaken in international airports in a middle-income country. The results are worse than those from the US study and do not have the limitations of lack of simultaneous monitoring and large smoking room areas that were reported as limitations in the US study.12 Yet, the limitations of this study include the naturalistic sampling and the fact that we monitored only DSRs that were active at the time of the research. However, the DSRs monitored were the most frequently used and did not differ markedly in size or design from DSRs not in use and not monitored. It is important to stress that SHS restriction is a workplace measure important to employers, employees and the public. In addition, because evaluation for occupational compliance is improving, Thailand should act now to ensure SHS levels are addressed to remove possible occupational threats and liabilities of such exposures in international airports.23 ,24 One implication of this study is that other countries, especially in Asia, should be aware of the possible high exposure levels in their international airports given that all large hub airports in Asia presently have smoking rooms or facilities.25

Conclusion

Findings show that just as in the USA, DSRs in Thailand fail to provide a safe, healthful environment inside airports for employees and international air travellers. Although many factors during the incremental changes to smoke-free policy in Thailand may be responsible for this gap in smoke-free coverage, our findings point to the need to put health and safety concerns first in addressing SHS in Thai airports. Arguments to block or delay smoke-free airports in Thailand are simply untenable in the face of such high SHS levels, and remedial steps must be taken if these high exposure levels are to be eliminated. Past smoke-free efforts in Thailand have resulted in research bringing recognition of the dangers of SHS, legislation that now prohibits smoking in most work and public places, and a future where other places (cars, multi-unit housing and homes) will become smoke free. From the Thai perspective, an important signal of the success of this advance is to finish the job of removing DSRs in airports.

What this paper adds

  • Provides specific environmental evidence about how badly airport designated smoking rooms fail in one middle-income country in comparison to recent findings from airports in the USA.

  • Highlights the need for remedial action to remove the serious environmental hazards of secondhand smoke which may affect airport workers, sensitive groups and an unsuspecting population of air travellers.

References

Footnotes

  • Contributors All authors made a substantial contribution to this research; HC, SP, NK and NC conceptualised/planned the study; NC, NK, JP and SH performed acquisition of data; ST, NK, NC and JP analysed and interpreted the data. All authors drafted/revised the manuscript and gave final approval to the version to be published.

  • Funding This work was supported by the Tobacco Control Research and Knowledge Management Center, Bangkok, Thailand. Additionally, the study was partially supported for publication by the China Medical Board (CMB), Faculty of Public Health, Mahidol University, Bangkok, Thailand.

  • Competing interests None.

  • Provenance and peer review Not commissioned; externally peer reviewed.

  • Data sharing statement Data from this study are available to colleagues interested in comparative work on a case by case basis.