Table 3

Air quality measures by number of active waterpipes in indoor venues (n=12), August–October 2012, Toronto Waterpipe Study

Air quality measuresStatisticsNumber of active waterpipes
01–45–910+
Total minutes measured (%)50.5 (3.5%)330.0 (22.8%)421.0 (29.1%)647.5 (44.7%)
PM2.5 (µg/m3)*Mean (SD)25.4 (14.1)138.7 (374.9)773.0 (842.8)2602.1 (2517.7)
Median28.038.0449.01966.0
Minimum–maximum7.0–48.09.0–3012.05.0–82007.0–17221.0
Ambient CO (ppm)*Mean (SD)0.4 (0.5)3.1 (4.9)13.4 (16.2)26.1 (23.2)
Median0.01.87.619.5
Minimum–maximum0.0–1.90.0–27.10.0–120.00.0–106.8
Nicotine (µg/m3)†Mean (SD)0.57 (0.35)3.21 (4.07)4.65 (1.67)
Median0.620.895.36
Minimum–maximum0.20–0.890.82–7.911.60–5.89
  • *PM2.5 and ambient CO were real-time measures and their means were time-weighted means.

  • †Air-nicotine levels were measured approximately 2 h in each venue. Its mean levels were calculated by the mean number of active waterpipes at each venue and then across venues.

  • CO, carbon monoxide.