Air pollution and cigarette smoke are recognized health risks. A method was developed for the measurement of the deposition fraction (DF) of polydisperse particulate matter (PM) in human airways. Ten normal volunteers [three females, age range 18-67 years, mean age (SD) 43.9 (14)] made single breath exhalations after inhalation to total lung capacity. The exhaled breath was diverted to a multichannel laser diffraction chamber where the particulate profiler measured 0.3 - 1.0-microm particles. DF was inversely related to expiration flow-rate, 0.69 (0.02) at 4 l min-1 and 0.5 (0.01) at 13 l min-1, respectively (p<0.05), and was influenced by the inhalation flow-rate [0.70 (0.02) at 3 l min-1 and 0.59 (0.02) at 13 l min-1, respectively (p<0.05)], while no differences were found between nasal and oral inhalation (0.68 (0.05) versus 0.67 (0.06), p>0.05). Higher breath holding times were associated with elevated DF [0.74 (0.02) at 20 s, and 0.62 (0.05) without breath holding (p<0.01)]. When the expiratory flow was controlled and the breath hold time standardized, DF was reproducible (CV = 4.85%). PM can be measured in the exhaled breath and its DF can be quantified using a portable device. These methods may be useful in studies investigating the health effects of air pollution and tobacco smoke.